Business DEX (LOGSA008):— facility Date: 2010/12/23 19:33:10
Revision: 1.20

Terms

For the purposes of this specification, the following terms apply:

alternate_logistics_support_analysis_control_number_code (ALC)
A code used to allow documentation of multiple models of a system/equipment, or alternate design considerations of an item, using the same LCN breakdown.
NOTE:
baseline_facility_maintenance_requirement_narrative
A description of the maintenance concept for the system/equipment under analysis and the facilities that are required to maintain the system. The narrative is a description identifying the maintenance concept for the system, e.g., number of maintenance levels, and identifying the facilities that are required to maintain the system at the applicable maintenance levels.
baseline_facility_requirements_for_operations_narrative
A narrative description of what facilities are needed to support the system in its daily use. This contains a narrative description identifying if the system is to be used or operated in garrison on a day-to-day basis and if such, what facilities are needed to support the system in its daily use, i.e., runways, helipads, clear zones, commercial power, operational pads, etc.
baseline_facility_requirements_for_training_narrative
A description of what facilities are needed for training; classrooms, ranges, maneuver areas; and, facilities for simulators or other training devices.
baseline_facility_requirements_special_considerations_narrative
A description of any special considerations that impact facility requirements. It is used to describe special problems that apply to facilities requirements. Such items may consist of item weight, turning radius, environmental impacts, and security requirements. Also, information concerning facility requirement interrelationships that identifies advantages of close proximity to other facilities from a functional/ efficiency standpoint or site restrictions such as quantity distance criteria is identified.
baseline_facility_requirements_supply_storage_narrative
A description of where the system/equipment will be stored, e.g., arms room, motor pool; or if there is an impact in other storage facilities. This element describes if there are any special storage requirements for the system or components; e.g., security, environmental controls, warehouse, covered, uncovered, or if there is any impact in other storage facilities; e.g., petroleum, oil, lubricants, munitions.
document_id
A designation assigned to a particular drawing or document by the authoritive source for identification purposes. The document id may include numbers, letters, and dashes.
end_item_acronym_code (EIAC)
A code that uniquely identifies the system/equipment end item. This code will be assigned by the requiring authority. It will remain constant throughout the item's life cycle (e.g., TOW, PATRIOT, Tomahawk, Sparrow, and ALCM).
facility_area
A numeric value describing the size of a designated space such as a shop, building, or land parcel in units contained in the associated Unit of Measure.
facility_capability_narrative
A description of the capacity impact on the work load of the facility.
facility_category_code
Provides a method for identifying and classifying real property from the initial planning stages through the complete cycle of programming, budgeting, accounting, and reporting in the areas of acquisition, construction, inventory, and maintenance. Every report entity item of real property is considered a facility. A parcel of land is a facility, as is each building, structure, and utility constructed on or in the land. The three-digit DOD Basic Category codes have been extended within the services by additional digits. The more definitive categorization is authorized by DOD for internal use within the DOD components (see AR 415-28 or NAVFAC P-72 for codes).
facility_class
This is the short name used in conjunction with the facility category code within AR 415-28 and NAVFAC P-72 for identifying facility real property.
facility_construction_unit_of_measure_price
The best estimated price for facility constucion based upon the unit of measure.
facility_drawing_classification
A three-position code used to indicate the category and form or level of the engineering drawings used in the analysis. The code is divided into three subcategories as follows:

Code

Description

A

Design Evaluation

B

Interface Control

C

Service Test

D

Logistic Support

E

Procurement (identical items)

F

Procurement (interchangeable items)

G

Installation

H

Maintenance

I

Government Manufacture

J

Interchangeability Control

Table — Position 1. Intended Use Categories

Code

Description

1

Conceptual and Development Design

2

Production Prototype and Limited Production

3

Production

Table — Position 2. Drawing Level

Code

Description

Y

Proprietary

N

Nonproprietary

Table — Position 3: Proprietary Status - Facility drawings will not be coded as proprietary without prior review and approval of the requiring authority.

facility_drawing_number
A designation assigned to a particular drawing by the design activity for identification purposes. The drawing number may include numbers, letters and dashes with the following limitations:
facility_drawing_revision
the revision of a facility drawing
facility_location_narrative
A description of the existing depot facility in terms of where the facility is located (e.g., depot name, building, bay, etc.).
facility_name
An identification of the name of the facility type that the system/ equipment requires.
facility_type
A code identifying the facility type: operational, test, training, or depot.

Code

Description

A

Test Facility

B

Operational Facility

C

Training Facility

D

Depot Facility

Table — Facility Type

logistics_support_analysis_control_number (LCN)
A code that represents a functional or hardware generation breakdown/disassembly sequence of system/equipment hardware including SE, training equipment, and installation (connecting) hardware. For additional information on assignment of LCN, refer to the GEIA-HB-0007.
logistics_support_analysis_control_number_type (LCN Type)
A code indicating whether the LCN is representative of either a physical or functional breakdown.

Code

Description

P

Physical

F

Functional

Table — Logistics Support Analysis Control Number Type

new_or_modified_facility_design_criteria_narrative
A description of the facilitydesign requirements necessary to support the item under analysis. The design criteria are in terms, such as, axle loads, hoist requirements, and special handling, installation, storage, electrical, environmental, or service requirements.
new_or_modified_facility_installation_lead_time_narrative
A description of the facilities installation lead time schedules for contractor produced and installed support, test equipment, and training devices. Lead times are referenced to system/equipment delivery schedules rather than to calendar dates (expressed in days, weeks, or months).
new_or_modified_facility_justification_narrative
A narrative field that identifies the major factors that led to the decision that a new facility was required.
new_or_modified_facility_requirements_narrative
A description of the location of and the functions to be performed at the new or modified facility. Identifies environmental consideration affecting health, sanitation, or the surrounding community.
new_or_modified_facility_task_area_breakdown_narrative
A narrative description identifying the breakdown of a new or modified facility for the area by individual tasks at the job level to determine maximum use of space.
new_or_modified_facility_type_of_construction_narrative
A description of what type of construction is required at a new or modified facility. Included are estimated number of years the facility will be needed, required or preferred locations, and need for relocatability, and identification of any estimated future expansion. Provides information on any special construction, such as shock, hardness, and special floor loads.
new_or_modified_facility_unit_cost_rationale_narrative
A narrative field identifying variations to the appropriate unit cost contained in the military construction guides, in terms of differences because of unusual utilities requirements, or other special features. When a suitable unit cost is not available, provide a unit cost estimate for each facility item.
new_or_modified_facility_utilities_requirement_narrative
A narrative description identifying an estimate of the utilities required for a new or modified facility. This description contains an estimate of the total connected load, or other gross quantity of utilities required for each facility. Includes any unusual or critical requirements, energy conservation requirements, and continuous power requirements. Provides specific identification of the class of utility, e.g., electric power, hydraulic power, compressed air, water, and sewage.
new_or_modified_facility_utilization_narrative
A description of the new or modified facility utilization rate in terms of number of tasks performed in the facility, training sessions, flying hours, number of maintenance hours, and other appropriate designators per specified time period.
task_code
A data chain of six separate data subfields that uniquely identify each operator/maintenance task associated with particular items under analysis. The first five subfields provide information relative to the performance of the task itself. The sixth subfield is a task sequence code provided to differentiate tasks with identical entries in the first five subfields.

Additional terms used in the Help/Information pages.

NOTE   These terms are not part of the released specification.

© OASIS 2010 — All rights reserved