Template:— assigning_work_output (awout) Capability:representing_activity | 
            Date: 2010/01/14 16:30:11  Revision: 1.17 
             | 
         
      
      
      
         This section specifies the template assigning_work_output.
         
      
      
         NOTE 
         The template has been defined in the context of the capability 
         representing_activity
         which provides an overall description of the 
         relevant parts of the ISO 10303-239 information model and a description 
         of related templates.
         
      
      
         NOTE 
         An explanation of a template and the associated instantiation path is
         provided in the 
         Template overview
         section.
         
      
      
      
                  
         This template describes how to represent the output from work that has been done.
                  
         NOTE   
            The outputs referred to here are items that do not affect the configuration status of
                         the product that have been worked on. 
         
              
       
      
      
         The EXPRESS-G diagram in
         Figure 
1
         shows the templates and EXPRESS entities that are required
         to represent the template 
         "assigning_work_output".
         The text highlighted in blue shows the template parameters.
         
      
         
Figure 1 —  An EXPRESS-G representation of the Information model for assigning_work_output
         The graphic for the template to be used in other EXPRESS-G diagrams
         is shown in Figure 
         
2
         below.
         
      
 
      
                      
      
         
Figure 2 —  The graphical representation of the assigning_work_output template
      
         The following input parameters are defined for this template:
         
      
      
      
         
                             The class name corresponding to the type of the 
                             
Work_output. For example, oil,
                             Gypsum, swarf etc.
                         
         
 
       
      
         
            The following classes and their sub-classes can be used:
            
         
         
       
      ecl_id (Default=urn:plcs:rdl:std,Type='URN')
      
 
      
          The identifier of the 
External_class_library storing the
                             definition of the class referenced by the parameter @class_name.
                         
         
 
       
      
      
         
                             The activity that gave or will give rise to the 
                             
Work_output.
                         
         
 
       
      
      
         The following reference parameters are defined for this template:
         
      
      
      
         
            Allow the 
            
Work_output_assignment
            entity instantiated in this path to be referenced when this template is used. 
            
         
 
         
         %^target = $assigning_work_output.work_asg%
         
       
      
      
      
         
            Allow the 
            
Work_output
            entity instantiated in this path to be referenced when this template is used. 
            
         
 
         
            Note: The 
            
Work_output
            entity can be referenced in a template path by:
            
         
 
         %^target = $assigning_work_output.work_output%
         
            where 
            
target 
            is the parameter to which the 
            
Work_output
            is bound.
            
         
 
       
      
      
      
         The instantiation path shown below specifies the entities that are to be
         instantiated by the template.
         
      
      
         A description of templates and the syntax for the instantiation path is
         provided in the 
         
         
         
            Templates  Help/Information section.
         
      
 
      
      
         The following entities are instantiated with attributes as specified:
         
         
       
      
      
         The instance diagram in Figure 
         
3
         shows an example of the EXPRESS entities and templates that are instantiated by the template:       
         
         
/assigning_work_output(activity_item='#2', class_name='oil', ecl_id='urn:plcs:rdl:sample')/
         (an illustration of the consolidated assigning_work_output template is shown in 
         
         
         Figure 
4 below.)
         
      
         
Figure 3 —  Entities instantiated by assigning_work_output template
      
         The instance diagram in 
         Figure 
4
         shows the graphic symbol for the template that is to be
         used in other instance diagrams. The example template is:
         
         
         
/assigning_work_output(activity_item='#2', class_name='oil', ecl_id='urn:plcs:rdl:sample')/
      
         
Figure 4 —  Entities instantiated by assigning_work_output template
      
         The following section details how the 
         assigning_work_output
         template can be optionally characterized by assigning
         other constructs to it. These are characterizations commonly
         applied to the template. The ISO 10303-239 EXPRESS model may enable
         other assignments to the entities instantiated by the template.
         
      
      
         The EXPRESS-G diagram in Figure 
         
5
         shows the possible characterizations of the template 
         "assigning_work_output".
         
      
         
Figure 5 —  Characterizations for assigning_work_output
         The following characterizations may apply:
         
         
Characterization Assigning Identification
         
            
               NOTE   this characterization is optional.
               
            
          
         
         Characterization Representing Quantity
         
            
               NOTE   this characterization is optional.